Close
Online message
If you have any needs, please leave a message and we will contact you as soon as possible。
Maximum inlet pressure (bar) : 350
Rated flow rate of oil inlet (L/min) : 160
Priority work oil port maximum pressure (bar) : 240
Priority work oil port flow rate (L/min): 80
Using a PTO power take-off port can save space even more.
Implement priority control for traffic allocation.
Ensure safer and more reliable steering function.
Can be used for quantitative and variable pump systems.
| Control spring pressure(bar) | 7 | |
| P port rated flow(L/min) | 160 | |
| CF port rated flow(L/min) | 80 | |
| Maximum pressure at port(bar) | P port | 350 |
| EF port | 350 | |
| CF port | 240 | |
| LS port | 240 | |
| T port | 15 | |
| PP port | 210 | |
| Cleanliness | MAX ISO4406 18/15 | |