Shopping Cart
Global Site
Hengli America InLine Hydraulik Hattori Seiko Lixin Hydraulics Hengli Pneumatic Harada Seal
Language
简体中文 Deutsch Français Italiano 日本語 Русский язык Español Português
Close

Online message

If you have any needs, please leave a message and we will contact you as soon as possible。

Set the following parameters

2WRCE...L1X Type 2-way high-response Proportional cartridge valve, pilot operated

Series of pictures

Valves of type 2WRCE...-L1X/P... are 2-stage high-response valves. They control the quantity and direction of a flow and are mainly used in control loops.

Specifications: 25~100

Pressure: to 350 bar

Flow: up to 8000 L/min

Configure model/order number

***********
Copy to clipboard
Configured parameter:******
Open All | Close All

Serial Advantage

  • Pilot operated 2-way high-response valve in block installation design

  • Suitable for closed-loop controlling of position, pressure, force and velocity

  • Pilot control valve (pilot):

    Directly actuated controlled directional valve, with control spool and sleeve in servo quality

  • Main stage: closed-loop position controlled

  • Integrated open and closed-loop control electronics (OBE)

  • Typical applications:

    ·Plastic injection machines

    ·Die-casting machines

    ·Ceramics machines

Technical Specification

General
Size253240506380100
WeightWithout shut-off valve ...../...K or .../...Lkg8.511.217.324.64774110
With   shut-off valve
...../...WK or .../...WL...
kg9.812.518.625.96087123
Size   of the pilot control valve (pilot)NG6
Installation   positionAny, preferably   horizontal
Storage   temperature range–20 to +80
Ambient   temperature range–20 to +50

Hydraulic (measured with HLP32, ϑoil =40℃ ±5℃ )
Maximum   operating
    pressures
– Main stage ports A, Bbar350
– Pilot   control valve port Xbar315
– Pilot   control valve port Ybar35
Rated   flow at Δp = 5 bar– Design ...S...L (linear)L/min50080012002000360045008000
– Design   ...S...R
    (linear with progressive fine control range)
-6008501400320039006800
Nominal   flow of pilot valve at Δp=70 barL/min12124040100100100
Leakage   of pilot valve at P = 100 barL/min0.30.30.70.7111
Hydraulic   fluidMineral oil (HL, HLP)   to DIN 51524
Hydraulic   fluid temperature range–20 to +80; preferably   +40 to +50
Viscosity   rangemm2/s20 to 380; preferably   30 to 45
Max.   admissible degree of contamination of the
    hydraulic fluid, cleanliness class according to ISO 4406 (c)
Class 20/18/15
Hysteresis%≤ 0.2
Range   of inversion%≤ 0.1
Response   sensitivity%≤ 0.1
Response   time 0 ~ 100% step signalms25283030354050
Electrical
Cyclic   duration factor%100 ED
Degree   of protectionIP 65 to DIN 40050 and   IEC 14434/5
Solenoid   connectionPlug-in connector to   DIN 43650/ISO 4400,
    M16X1.5 (2P+PE)
Valve   with solenoid type0.8A2.5A
Max.   solenoid currentImax0.8A2.5A
Coil   resistance R20Ω223
Max. power   consumption at 100%
    load and operating temperature
VA2530




Static/Dynamic
Hysteresis%≤ 4 
Range of   inversion%≤ 3 
Manufacturing   tolerance for Pmax%≤ 10
Response   time 100% signal changemsOn 200 / Off <250

Application Industry

Be mainly used in
Close

Data Download