• Directioanl valve directioanl the oil path by controlling the main spool • WEH electrohydraulic control • Two-position four-way or three-position four-way • Installation face follow DIN 24340 A, ISO 4401 and CETOP-RP 121H Sub-plate mounting connection • Replace coil without releasing oil
Technical Specs
NG10
Working pressureP,A,B
bar
315
280
Port T
With external pilot oil drain
bar
315
250
With internal pilot oil drain
bar
210 AC 160
Port Y
With external pilot oil drain
bar
210
Min. control pressure
With external pilot oil supply
With internal pilot oil supply
(not apply to C, Z, F, G, H, P, T, V)
bar
3-position valve 10
Spring-return 2-position valve 10
Hydraulic-return 2-position valve 7
With internal pilot oil supply ( apply to C, Z, F, G, H, P, T, V)
bar
4.5
Max. control pressure
bar
250
Fluid
Mineral oil,Phosphate ester
Fluid temperature range
℃
-30 to +80 ( NBR seals
-20 to +80 ( FKM seals )
Viscosity range
mm2/s
2.8 to 500
Controlled quantity in commutating process
cm3
3-position valve 2.04 2-position valve 4.08
Switching times (= Valve switching time from the neutral position to the switched position)(DC )
Control pressure
bar
70
140
210
250
3-position valve
ms
65
60
55
50
2-position valve
ms
80
75
70
65
Switching times (= Valve switching time from the switched position to the neutral position)
3-position valve
ms
30
2-position valve
ms
35
40
30
35
25
30
20
25
Flow of shortest switching time
L/min
about 35
Installation position
HC, HD, HK, HZ and HY of hydraulic return shall be installed horizontally. The rest are arbitrary
Weight
kg
about 9.5
NG16
Specifications
G-H-...WEH16../6B2... type
G-..WEH16../6B2.. type
Working pressureP,A,B bar
350
280
Port T
With external pilot oil drain bar
250
250
With internal pilot oil drain bar
210
Hydraulic-centering 3-position valve With internal pilot oil drain is impossible
Port Y
With external pilot oil drain bar
210
Min. control pressure
With external pilot oil supply bar
With internal pilot oil supply bar
3-position valve 14
Spring-return 2-position valve 14
Hydraulic-return 2-position valve 14
With internal pilot oil supply ( apply to C、Z、F、G、H、P、T、V) bar
When applying back pressure valve or the flow is large, enginery of spool valve is 4.5 bar as C、Z、F、G、H、P、T and V
Max. control pressure bar
250
Fluid
Mineral oil,Phosphate ester
Fluid temperature range ℃
-30 to +80 ( NBR seals
-20 to +80 ( FKM seals )
Viscosity range mm2
/s 2
2.8 to 500
Switching pilot oil volume
-Spring-centering 3-position valve cm3
5.72
-2-position valve cm3
11.45
Hydraulic-centering 3-position valve
- From"0"position to working position"a" cm3
2.83
- From working position"a" to "0"position cm3
2.9
- From"a"position to working position"b" cm3
5.72
- From working position"b" to "0"position cm3
2.83
* Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC)
Control pressure bar
50
150
250
- Spring-centering 3-position valve ms
65
60
58
- 2-position valve ms
65
55
50
- Spring-centering 3-position valve ms
a
b
a
b
a
b
65
65
55
63
55
60
**Switching times (= Valve switching time from the neutral position to the switched position)
- Spring-centering 3-position valve ms
40
- 2-position valve ms
45
35
30
- Hydraulic-centering 3-position valve ms
a
b
a
b
a
b
20
20
20
20
20
20
Installation position
C,D,K,Z,Y Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily。
Flow of shorter switching time L/min
about 35
Weight of the valve kg
about 10.6
NG25
Specifications
G-H-...WEH25../6B2... type
G-..WEH25../6B2.. type
Working pressureP,A,B bar
350
280
Port T
With external pilot oil drain bar
250
250
With internal pilot oil drain bar
210
Hydraulic-centering 3-position valve With internal pilot oil drain is impossible
Port Y
With external pilot oil drain bar
210
Min. control pressure
With external pilot oil supply bar
With internal pilot oil supply bar
Spring-centering 3-position valve 13
Hydraulic-centering 3-position valve 18
Spring-return 2-position valve 13
Hydraulic-return 2-position valve 18
With internal pilot oil supply
When applying back pressure valve or the flow is large, enginery of spool valve is 4.5 bar as C、Z、F、G、H、P、T and V
Max. control pressure bar
250
Fluid
Mineral oil,Phosphate ester
Fluid temperature range ℃
-30 to +80 ( NBR seals
-20 to +80 ( FKM seals )
Viscosity range mm2
/s 2
2.8 to 500
Switching pilot oil volume
-Spring-centering 3-position valve cm3
14.2
-2-position valve cm3
28.4
Hydraulic-centering 3-position valve
- From"0"position to working position"a" cm3
7.15
- From working position"a" to "0"position cm3
7.0
- From"a"position to working position"b" cm3
14.15
- From working position"b" to "0"position cm3
5.73
* Switching times (= Valve switching time from the neutral position to the switched position)(AC and DC)
Control pressure bar
50
140
210
250
- Spring-centering 3-position valve ms
85
75
70
65
- 2-position valve ms
160
130
120
105
- Spring-centering 3-position valve ms
a
b
a
b
a
b
a
b
55
65
55
65
50
60
50
60
**Switching times (= Valve switching time from the neutral position to the switched position)
- Spring-centering 3-position valve ms
40
- 2-position valve ms
125
100
90
80
- Hydraulic-centering 3-position valve ms
a
b
a
b
a
b
a
b
30
35
30
35
30
35
30
35
Installation position
C,D,K,Z,Y Type hydraulic-return valves are installed horizontally, the rest can be installed arbitrarily。