• Used for bottom sub-plate mounting • Installation face follow DIN 24340 E and ISO 6264 • Used in screw connection, Used for bottom sub-plate mounting • Five pressure ranges • Unloading operation via a built-on solenoid directional valv • Two adjustment types: knob, adjustment screw with protection cap • Optional switching shock damping
Technical Specs
Installation position
Optional
Weight
G...DBW...10
G...DBW...15
G...DBW...20
G...DBW...25
G...DBW...30
Base sub-plate mounting
G...DBW
kg
about 5.6
-
about 6.5
-
about 7.9
threaded connection
G...DBW..G..
kg
about 7.9
about 7.8
about 7.7
about 8.5
about 8.4
Switching shock damping
kg
about 0.6
Technical parameters of directional valve
Refer to the solenoid valvetype G...WE6,normally close use G...3WE6A9, normally open use G...3WE6B9
Fluid
Mineral oil suitable for NBR and FKM seal
Phosphate ester for FKM seal
Fluid temperature range
℃
-30 to +80(NBR seal)
-20 to +80(FKM seal)
Viscosity range
mm2/s
10 to 800
Degree of contamination
Maximum permissible degree of fluid contamination:
Class 9. NAS 1638 or 20/18/15, ISO4406
Max. operating pressure
Port A, B, X, P
bar
350
Port Y or T DBW
bar
210
Max. setting pressure
bar
50; 100; 200; 315; 350
Min.
bar
Interrelated with Q(Refer to the characteristic curve)